HomeDaikin Fault Codes Daikin Fault Code List A0 l External protection device abnormality A1 l PCB abnormality A3 l Drain level control system (S1L) abnormality A6 l Fan motor (M1F) lock, overload A6 l Indoor unit fan motor abnormality A6 l Overload / overcurrent / lock of indoor unit fan motor A7 l Swing flap motor (M1S) abnormality A8 l Power supply voltage abnormality A9 l Electronic expansion valve coil abnormality / dust cloggingA9 l Electronic expansion valve coil abnormality AF l Drain level above limit AJ l Capacity determination device abnormality C1 l Transmission abnormality between indoor unit PCB and fan PCBC4 l Heat exchanger liquid pipe thermistor abnormality C5 l Heat exchanger gas pipe thermistor abnormality C6 l Combination error between indoor unit PCB and fan PCB C9 l Suction air thermistor abnormality Remote sensor abnormalityCA l Thermistor abnormalityCC l Humidity sensor system abnormality CJ l Room temperature thermistor in remote controller abnormality E1 l PCB abnormality E3 l Actuation of high pressure switch E4 l Actuation of low pressure sensor E5 l INV compressor motor lock E6 l Compressor damage alarm E7 l Outdoor unit fan motor abnormality E9 l Electronic expansion valve coil abnormality F3 l Discharge pipe temperature abnormalityF4 l Wet alarmF6 l Refrigerant overcharged H3 l Harness abnormality (between control PCB and inverter PCB) H7 l Outdoor unit fan motor signal abnormalityH9 l Outdoor air thermistor (R1T) abnormalityJ3 l Discharge pipe thermistor (R21T, R22T, R2T) abnormalityCompressor surface temperature thermistor (R14T) abnormalityJ5 l Compressor suction thermistor (R12T) abnormalitySuction air thermistor (R10T) abnormalityJ6 l Heat exchanger deicer thermistor (R11T) abnormalityHeat exchanger gas pipe thermistor (R8T, R9T) abnormalityJ7 l Receiver inlet thermistor (R3T) abnormalitySubcooling heat exchanger liquid pipe thermistor (R7T) abnormalityJ8 l Heat exchanger liquid pipe thermistor (R4T, R5T) abnormalityJ9 l Subcooling heat exchanger gas pipe thermistor (R6T) abnormalityReceiver gas purge thermistor (R13T) abnormalityJA l High pressure sensor abnormality JC l Low pressure sensor abnormality L1 l Inverter PCB abnormality L3 l Reactor temperature rise abnormalityL4 l Inverter radiation fin temperature rise abnormality L5 l INV compressor instantaneous overcurrentL8 l INV compressor overcurrentL9 l INV compressor startup abnormality LC l Transmission error between inverter and control PCB P1 l Power supply voltage imbalance P3 l Reactor Temperature Abnormality P4 l Inverter radiation fin temperature abnormalityPJ l Field setting after replacing outdoor unit main PCB abnormality or combination of PCB abnormality SystemU0 l Refrigerant shortageU1 l Reverse phase, open phaseU2 l Power supply insufficient or instantaneous abnormality U3 l Check operation is not executedU4 l Transmission error between indoor units and outdoor units U5 l Transmission error between remote controller and indoor unit U7 l Transmission error between outdoor unitsU8 l Transmission error between main and sub remote controllers U9 l Transmission error between indoor and outdoor units in the same systemUA l Improper combination of indoor and outdoor units, indoor units and remote controllerUC l Address duplication of centralized control equipment UE l Transmission error between centralized control equipment and indoor unitUF l System is not set yetUH l System abnormality, refrigerant system address undefined